2026 . 11 . 16
Covering Materials and Inoculants in Ductile Iron Treatment
Nodularizers, covering materials and inoculants may be used within one treatment process, but their function, grade and addition point should be checked separately. Similar names do not establish interchangeability.
Document the existing process
Record the ladle configuration, base iron composition, treatment weight and current materials. Keep existing operating parameters and maintain traceable records for material trials.
A covering inoculant is a specific product
Our Silibest 50 entry describes a covering inoculant within the New Alloy range. Its data cannot establish the composition or application of another brand’s covering material, or make it equivalent to a slag remover.
Make comparisons traceable
Record material name, batch, addition quantity, particle size, sampling times, temperatures and inspection results together. Note any simultaneous changes in conditions so that a result is not attributed to one material without evidence.
Prepare an enquiry
Provide current labels, technical data, the process outline and the problem to be reviewed. This note supplies no universal addition rate or unverified performance comparison.